Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 772
Filter
1.
Phys Med Biol ; 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38663411

ABSTRACT

OBJECTIVE: Deep-learning networks for super-resolution (SR) reconstruction enhance the spatial-resolution of 3D magnetic resonance imaging (MRI) for MR-guided radiotherapy (MRgRT). However, variations between MRI scanners and patients impact the quality of SR for real-time 3D low-resolution (LR) cine MRI. In this study, we present a personalized super-resolution (psSR) network that incorporates transfer-learning to overcome the challenges in inter-scanner SR of 3D cine MRI. Approach: Development of the proposed psSR network comprises two-stages: 1) a cohort-specific SR (csSR) network using clinical patient datasets, and 2) a psSR network using transfer-learning to target datasets. The csSR network was developed by training on breath-hold and respiratory-gated high-resolution (HR) 3D MRIs and their k-space down-sampled LR MRIs from 53 thoracoabdominal patients scanned at 1.5 T. The psSR network was developed through transfer-learning to retrain the csSR network using a single breath-hold HR MRI and a corresponding 3D cine MRI from 5 healthy volunteers scanned at 0.55 T. Image quality was evaluated using the peak-signal-noise-ratio (PSNR) and the structure-similarity-index-measure (SSIM). The clinical feasibility was assessed by liver contouring on the psSR MRI using an auto-segmentation network and quantified using the Dice-similarity-coefficient (DSC). Results. Mean PSNR and SSIM values of psSR MRIs were increased by 57.2% (13.8 to 21.7) and 94.7% (0.38 to 0.74) compared to cine MRIs, with the reference 0.55 T breath-hold HR MRI. In the contour evaluation, DSC was increased by 15% (0.79 to 0.91). Average time consumed for transfer-learning was 90 s, psSR was 4.51 ms per volume, and auto-segmentation was 210 ms, respectively. Significance. The proposed psSR reconstruction substantially increased image and segmentation quality of cine MRI in an average of 215 ms across the scanners and patients with less than 2 minutes of prerequisite transfer-learning. This approach would be effective in overcoming cohort- and scanner-dependency of deep-learning for MRgRT. .

2.
Indian J Community Med ; 49(2): 255-259, 2024.
Article in English | MEDLINE | ID: mdl-38665454

ABSTRACT

Cinema has the ability to convey important messages in an engaging and interesting manner. Cine medicine also known as cinema medicine or Cinemeducation has the potential to teach medical students and healthcare professionals about various aspects of medical conditions and illnesses. It is an innovative approach that can enhance empathy among the students and understanding toward patients with various medical conditions. Indian cinema has played a significant role in promoting health awareness and educating people about various medical conditions. Cinemeducation/Cine medicine can be instrumental in inculcating ethics and professionalism among budding clinicians. Of late, medical educationists have understood its importance and have introduced this innovative method in teaching not only medical humanities but medicine per se. This article aims to summarize the strengths, weaknesses opportunities, and threats analysis of the cine medicine along with reviews of Indian cinema for emphasizing the medical condition depicted in these cinemas/movies.

3.
Article in English | MEDLINE | ID: mdl-38630210

ABSTRACT

Cardiac magnetic resonance cine images are primarily used to evaluate functional consequences, whereas limited information is extracted from the noncontrast pixel-wise myocardial signal intensity pattern. In this study we want to assess whether characterizing this inherent contrast pattern of noncontrast-enhanced short axis (SAX) cine images via radiomics is sufficient to distinguish subjects with acute myocardial infarction (AMI) from controls. Cine balanced steady-state free-precession images acquired at 1.5 T from 99 AMI and 49 control patients were included. First, radiomic feature extraction of the left ventricular myocardium of end-diastolic (ED) and end-systolic (ES) frames was performed based on automated (AUTO) or manually corrected (MAN) segmentations. Next, top features were selected based on optimal classification results using a support vector machine (SVM) approach. The classification performances of the four radiomics models (using AUTO or MAN segmented ED or ES images), were measured by AUC, classification accuracy (CA), F1-score, sensitivity and specificity. The most accurate model was found when combining the features RunLengthNonUniformity, ClusterShade and Median obtained from the manually segmented ES images (CA = 0.846, F1 score = 0.847). ED analysis performed worse than ES, with lower CA and F1 scores (0.769 and 0.770, respectively). Manual correction of automated contours resulted in similar model features as the automated segmentations and did not improve classification results. A radiomics analysis can capture the inherent contrast in noncontrast mid-ventricular SAX cine images to distinguishing AMI from healthy subjects. The ES radiomics model was more accurate than the ED model. Manual correction of the autosegmentation did not provide significant classification improvements.

4.
Acta Crystallogr E Crystallogr Commun ; 80(Pt 4): 435-438, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38584740

ABSTRACT

The title compound, C22H18N2O12, was obtained as a by-product during the planned synthesis of 1,2-bis-(2-nitro-4,5-dimethyl phthalate)ethane by oxidative dimerization starting from dimethyl-4-methyl-5-nitro phthalate. To identify this compound unambiguously, a single-crystal structure analysis was performed. The asymmetric unit consists of half a mol-ecule that is located at a centre of inversion. As a result of symmetry restrictions, the mol-ecule shows an E configuration around the double bond. Both phenyl rings are coplanar, whereas the nitro and the two methyl ester groups are rotated out of the ring plane by 32.6 (1), 56.5 (2) and 49.5 (2)°, respectively. In the crystal, mol-ecules are connected into chains extending parallel to the a axis by pairs of C-H⋯O hydrogen bonds that are connected into a tri-periodic network by additional C-H⋯O hydrogen-bonding inter-actions.

5.
Magn Reson Imaging ; 111: 15-20, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38579974

ABSTRACT

BACKGROUND: In patients who have difficulty holding their breath, a free breathing (FB) respiratory-triggered (RT) bSSFP cine technique may be used. However, this technique may have inferior image quality and a longer scan time than breath-hold (BH) bSSFP cine acquisitions. This study examined the effect of an audiovisual breathing guidance (BG) system on RT bSSFP cine image quality, scan time, and ventricular measurements. METHODS: This study evaluated a BG system that provides audiovisual instructions and feedback on the timing of inspiration and expiration to the patient during image acquisition using input from the respiratory bellows to guide them toward a regular breathing pattern with extended end-expiration. In this single-center prospective study in patients undergoing a clinical cardiac magnetic resonance examination, a ventricular short-axis stack of bSSFP cine images was acquired using 3 techniques in each patient: 1) FB and RT (FBRT), 2) BG system and RT (BGRT), and 3) BH. The 3 acquisitions were compared for image quality metrics (endocardial edge definition, motion artifact, and blood-to-myocardial contrast) scored on a Likert scale, scan time, and ventricular volumes and mass. RESULTS: Thirty-two patients (19 females; median age 21 years, IQR 18-32) completed the study protocol. For scan time, BGRT was faster than FBRT (163 s vs. 345 s, p < 0.001). Endocardial edge definition, motion artifact, and blood-to-myocardial contrast were all better for BGRT than FBRT (p < 0.001). Left ventricular (LV) end-systolic volume (ESV) was smaller (3%, p = 0.02) and LV ejection fraction (EF) was larger (0.5%, p = 0.003) with BGRT than with FBRT. There was no significant difference in LV end-diastolic volume (EDV), LV mass, right ventricular (RV) EDV, RV ESV, and RV EF. Scan times were shorter for BGRT compared to BH. Endocardial edge definition and blood-to-myocardial contrast were better for BH than BGRT. Compared to BH, the LV EDV, LV ESV, RV EDV, and RV ESV were mildly smaller (all differences <7%) for BGRT. CONCLUSIONS: The addition of a BG system to RT bSSFP cine acquisitions decreased the scan time and improved image quality. Further exploration of this BG approach is warranted in more diverse populations and with other free breathing sequences.

6.
J Magn Reson Imaging ; 2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38436994

ABSTRACT

BACKGROUND: Balanced steady-state free precession (bSSFP) imaging is commonly used in cardiac cine MRI but prone to image artifacts. Ferumoxytol-enhanced (FE) gradient echo (GRE) has been proposed as an alternative. Utilizing the abundance of bSSFP images to develop a computationally efficient network that is applicable to FE GRE cine would benefit future network development. PURPOSE: To develop a variable-splitting spatiotemporal network (VSNet) for image reconstruction, trained on bSSFP cine images and applicable to FE GRE cine images. STUDY TYPE: Retrospective and prospective. SUBJECTS: 41 patients (26 female, 53 ± 19 y/o) for network training, 31 patients (19 female, 49 ± 17 y/o) and 5 healthy subjects (5 female, 30 ± 7 y/o) for testing. FIELD STRENGTH/SEQUENCE: 1.5T and 3T, bSSFP and GRE. ASSESSMENT: VSNet was compared to VSNet with total variation loss, compressed sensing and low rank methods for 14× accelerated data. The GRAPPA×2/×3 images served as the reference. Peak signal-to-noise-ratio (PSNR), structural similarity index (SSIM), left ventricular (LV) and right ventricular (RV) end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were measured. Qualitative image ranking and scoring were independently performed by three readers. Latent scores were calculated based on scores of each method relative to the reference. STATISTICS: Linear mixed-effects regression, Tukey method, Fleiss' Kappa, Bland-Altman analysis, and Bayesian categorical cumulative probit model. A P-value <0.05 was considered statistically significant. RESULTS: VSNet achieved significantly higher PSNR (32.7 ± 0.2), SSIM (0.880 ± 0.004), rank (2.14 ± 0.06), and latent scores (-1.72 ± 0.22) compared to other methods (rank >2.90, latent score < -2.63). Fleiss' Kappa was 0.52 for scoring and 0.61 for ranking. VSNet showed no significantly different LV and RV ESV (P = 0.938) and EF (P = 0.143) measurements, but statistically significant different (2.62 mL) EDV measurements compared to the reference. CONCLUSION: VSNet produced the highest image quality and the most accurate functional measurements for FE GRE cine images among the tested 14× accelerated reconstruction methods. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.

7.
Phys Med ; 120: 103343, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38547546

ABSTRACT

PURPOSE: Stereotactic radiotherapy (SRT) has transformed cancer treatment, especially for brain metastases. Ensuring accurate SRT delivery is crucial, with the Winston-Lutz test being an important quality control tool. Off-axis Winston-Lutz (OAWL) tests are designed for accuracy assessment, but most are limited to fixed angles and hampered by local-field shifts caused by suboptimal Multi-Leaf Collimator (MLC) positioning. This study introduces a new OAWL approach for quality control in multi-brain-metastasis SRT. Utilizing cine Electronic Portal Imaging Device (EPID) images, it can be used with dynamic conformal arc (DCA) therapy. However, dynamic OAWL (DOAWL) is prone to more local-field shifts due to dynamic MLC movements. A two-step DOAWL is proposed: step 1 calculates local-field shifts using dynamic MLC movements in the beam-eye view data from the Treatment Planning System (TPS), while step 2 processes cine EPID images with an OAWL algorithm to isolate true deviations. METHODS: Validation involved an anthropomorphic head phantom with metallic ball-bearings, Varian TrueBeam STx accelerator delivering six coplanar/non-coplanar DCA beams, cine EPID, and ImageJ's OAWL analysis algorithm. RESULTS: Inherent local-field shifts ranged from 0.11 to 0.49 mm; corrected mean/max EPID-measured displacement was 0.34/1.03 mm. Few points exceeded 0.75/1.0-mm thresholds. CONCLUSIONS: This two-step DOAWL test merges cine-EPID acquisitions, DCA, OAWL, and advanced analysis and offers effective quality control for multi-brain-metastasis SRT. Its routine implementation may also improve physicist knowledge of the treatment precision of their machines.


Subject(s)
Brain Neoplasms , Radiosurgery , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Conformal/methods , Diagnostic Imaging , Phantoms, Imaging , Quality Control , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
8.
Phys Med Biol ; 69(8)2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38518378

ABSTRACT

Objective.In this study, we tackle the challenge of latency in magnetic resonance linear accelerator (MR-Linac) systems, which compromises target coverage accuracy in gated real-time radiotherapy. Our focus is on enhancing motion prediction precision in abdominal organs to address this issue. We developed a convolutional long short-term memory (convLSTM) model, utilizing 2D cine magnetic resonance (cine-MR) imaging for this purpose.Approach.Our model, featuring a sequence-to-one architecture with six input frames and one output frame, employs structural similarity index measure (SSIM) as loss function. Data was gathered from 17 cine-MRI datasets using the Philips Ingenia MR-sim system and an Elekta Unity MR-Linac equivalent sequence, focusing on regions of interest (ROIs) like the stomach, liver, pancreas, and kidney. The datasets varied in duration from 1 to 10 min.Main results.The study comprised three main phases: hyperparameter optimization, individual training, and transfer learning with or without fine-tuning. Hyperparameters were initially optimized to construct the most effective model. Then, the model was individually applied to each dataset to predict images four frames ahead (1.24-3.28 s). We evaluated the model's performance using metrics such as SSIM, normalized mean square error, normalized correlation coefficient, and peak signal-to-noise ratio, specifically for ROIs with target motion. The average SSIM values achieved were 0.54, 0.64, 0.77, and 0.66 for the stomach, liver, kidney, and pancreas, respectively. In the transfer learning phase with fine-tuning, the model showed improved SSIM values of 0.69 for the liver and 0.78 for the kidney, compared to 0.64 and 0.37 without fine-tuning.Significance. The study's significant contribution is demonstrating the convLSTM model's ability to accurately predict motion for multiple abdominal organs using a Unity-equivalent MR sequence. This advancement is key in mitigating latency issues in MR-Linac radiotherapy, potentially improving the precision and effectiveness of real-time treatment for abdominal cancers.


Subject(s)
Abdominal Neoplasms , Magnetic Resonance Imaging, Cine , Humans , Motion , Abdomen/diagnostic imaging , Abdominal Neoplasms/radiotherapy , Liver/diagnostic imaging , Magnetic Resonance Imaging/methods
9.
Math Biosci Eng ; 21(3): 3695-3712, 2024 Feb 18.
Article in English | MEDLINE | ID: mdl-38549302

ABSTRACT

The two-dimensional (2D) cine cardiovascular magnetic resonance (CMR) technique is the reference standard for assessing cardiac function. However, one challenge with 2D cine is that the acquisition time for the whole cine stack is long and requires multiple breath holds, which may not be feasible for pediatric or ill patients. Though single breath-hold multi-slice cine may address the issue, it can only acquire low-resolution images, and hence, affect the accuracy of cardiac function assessment. To address these challenges, a Ferumoxytol-enhanced, free breathing, isotropic high-resolution 3D cine technique was developed. The method produces high-contrast cine images with short acquisition times by using compressed sensing together with a manifold-based method for image denoising. This study included fifteen patients (9.1 $ \pm $ 5.6 yrs.) who were referred for clinical cardiovascular magnetic resonance imaging (MRI) with Ferumoxytol contrast and were prescribed the 3D cine sequence. The data was acquired on a 1.5T scanner. Statistical analysis shows that the manifold-based denoised 3D cine can accurately measure ventricular function with no significant differences when compared to the conventional 2D breath-hold (BH) cine. The multiplanar reconstructed images of the proposed 3D cine method are visually comparable to the golden standard 2D BH cine method in terms of clarity, contrast, and anatomical precision. The proposed method eliminated the need for breath holds, reduced scan times, enabled multiplanar reconstruction within an isotropic data set, and has the potential to be used as an effective tool to access cardiovascular conditions.


Subject(s)
Ferrosoferric Oxide , Magnetic Resonance Imaging, Cine , Humans , Child , Magnetic Resonance Imaging, Cine/methods , Imaging, Three-Dimensional/methods , Heart/diagnostic imaging , Respiration , Reproducibility of Results
10.
Phys Med Biol ; 69(9)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38479004

ABSTRACT

Objective. 3D cine-magnetic resonance imaging (cine-MRI) can capture images of the human body volume with high spatial and temporal resolutions to study anatomical dynamics. However, the reconstruction of 3D cine-MRI is challenged by highly under-sampled k-space data in each dynamic (cine) frame, due to the slow speed of MR signal acquisition. We proposed a machine learning-based framework, spatial and temporal implicit neural representation learning (STINR-MR), for accurate 3D cine-MRI reconstruction from highly under-sampled data.Approach. STINR-MR used a joint reconstruction and deformable registration approach to achieve a high acceleration factor for cine volumetric imaging. It addressed the ill-posed spatiotemporal reconstruction problem by solving a reference-frame 3D MR image and a corresponding motion model that deforms the reference frame to each cine frame. The reference-frame 3D MR image was reconstructed as a spatial implicit neural representation (INR) network, which learns the mapping from input 3D spatial coordinates to corresponding MR values. The dynamic motion model was constructed via a temporal INR, as well as basis deformation vector fields (DVFs) extracted from prior/onboard 4D-MRIs using principal component analysis. The learned temporal INR encodes input time points and outputs corresponding weighting factors to combine the basis DVFs into time-resolved motion fields that represent cine-frame-specific dynamics. STINR-MR was evaluated using MR data simulated from the 4D extended cardiac-torso (XCAT) digital phantom, as well as two MR datasets acquired clinically from human subjects. Its reconstruction accuracy was also compared with that of the model-based non-rigid motion estimation method (MR-MOTUS) and a deep learning-based method (TEMPEST).Main results. STINR-MR can reconstruct 3D cine-MR images with high temporal (<100 ms) and spatial (3 mm) resolutions. Compared with MR-MOTUS and TEMPEST, STINR-MR consistently reconstructed images with better image quality and fewer artifacts and achieved superior tumor localization accuracy via the solved dynamic DVFs. For the XCAT study, STINR reconstructed the tumors to a mean ± SD center-of-mass error of 0.9 ± 0.4 mm, compared to 3.4 ± 1.0 mm of the MR-MOTUS method. The high-frame-rate reconstruction capability of STINR-MR allows different irregular motion patterns to be accurately captured.Significance. STINR-MR provides a lightweight and efficient framework for accurate 3D cine-MRI reconstruction. It is a 'one-shot' method that does not require external data for pre-training, allowing it to avoid generalizability issues typically encountered in deep learning-based methods.


Subject(s)
Neoplasms , Respiration , Humans , Magnetic Resonance Imaging, Cine , Imaging, Three-Dimensional/methods , Motion , Phantoms, Imaging , Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods
11.
Article in English | MEDLINE | ID: mdl-38519293

ABSTRACT

Optimal surgical and medical management of obstructive sleep apnea (OSA) requires clinically reliable identification of patterns and sites of upper airway obstruction. A wide variety of modalities has been used to evaluate upper airway obstruction. Drug-induced sleep endoscopy (DISE) and cine MRI are increasingly used to identify upper airway obstruction sites, to characterize airway obstruction patterns, to determine optimum medical and surgical treatment, and to plan individualized surgical management. Here, the authors provide an overview of the applications of DISE and cine MRI in assessing upper airway obstruction in children and adults with OSA.

12.
Article in English | MEDLINE | ID: mdl-38485538

ABSTRACT

Optimal surgical and medical management of obstructive sleep apnea requires clinically reliable identification of patterns and sites of upper airway obstruction. A wide variety of modalities have been used to evaluate upper airway obstruction. Drug-induced sleep endoscopy (DISE) and cine MRI are increasingly used to identify upper airway obstruction sites, to characterize airway obstruction patterns, to determine optimum medical and surgical treatment, and to plan individualized surgical management. Here, we provide an overview of the applications of DISE and cine MRI in assessing upper airway obstruction in children and adults with obstructive sleep apnea.

13.
Insights Imaging ; 15(1): 75, 2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38499900

ABSTRACT

PURPOSE: The temporal evolution of ventricular trabecular complexity and its correlation with major adverse cardiovascular events (MACE) remain indeterminate in patients presenting with acute ST elevation myocardial infarction (STEMI). METHODS: This retrospective analysis enrolled patients undergoing primary percutaneous coronary intervention (pPCI) for acute STEMI, possessing cardiac magnetic resonance (CMR) data in the acute (within 7 days), subacute (1 month after pPCI), and chronic phases (6 months after pPCI) from January 2015 to January 2020 at the three participating sites. Fractal dimensions (FD) were measured for the global, infarct, and remote regions of left ventricular trabeculae during each phase. The potential association of FD with MACE was analyzed using multivariate Cox regression. RESULTS: Among the 200 analyzed patients (182 men; median age, 61 years; age range, 50-66 years), 37 (18.5%) encountered MACE during a median follow-up of 31.2 months. FD exhibited a gradual decrement (global FD at acute, subacute, and chronic phases: 1.253 ± 0.049, 1.239 ± 0.046, 1.230 ± 0.045, p < 0.0001), with a more pronounced decrease observed in patients subsequently experiencing MACE (p < 0.001). The global FD at the subacute phase correlated with MACE (hazard ratio 0.89 (0.82, 0.97), p = 0.01), and a global FD value below 1.26 was associated with a heightened risk. CONCLUSION: In patients post-STEMI, the global FD, serving as an indicator of left ventricular trabeculae complexity, independently demonstrated an association with subsequent major adverse cardiovascular events, beyond factors encompassing left ventricular ejection fraction, indexed left ventricular end-diastolic volume, infarct size, heart rate, NYHA class, and post-pPCI TIMI flow. CRITICAL RELEVANCE STATEMENT: In patients who have had an ST-segment elevation myocardial infarction, global fractal dimension, as a measure of left ventricular trabeculae complexity, provided independent association with subsequent major adverse cardiovascular event. KEY POINTS: • Global and regional FD decreased after STEMI, and more so in patients with subsequent MACE. • Lower global FD at the subacute phase and Δglobal FD from acute to subacute phase were associated with subsequent MACE besides clinical and CMR factors. • Global FD at the subacute phase independently correlated with MACE and global FD value below 1.26 was associated with higher risk.

14.
Eur Radiol ; 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38451322

ABSTRACT

OBJECTIVE: This work aimed to derive a machine learning (ML) model for the differentiation between ischemic cardiomyopathy (ICM) and non-ischemic cardiomyopathy (NICM) on non-contrast cardiovascular magnetic resonance (CMR). METHODS: This retrospective study evaluated CMR scans of 107 consecutive patients (49 ICM, 58 NICM), including atrial and ventricular strain parameters. We used these data to compare an explainable tree-based gradient boosting additive model with four traditional ML models for the differentiation of ICM and NICM. The models were trained and internally validated with repeated cross-validation according to discrimination and calibration. Furthermore, we examined important variables for distinguishing between ICM and NICM. RESULTS: A total of 107 patients and 38 variables were available for the analysis. Of those, 49 were ICM (34 males, mean age 60 ± 9 years) and 58 patients were NICM (38 males, mean age 56 ± 19 years). After 10 repetitions of the tenfold cross-validation, the proposed model achieved the highest area under curve (0.82, 95% CI [0.47-1.00]) and lowest Brier score (0.19, 95% CI [0.13-0.27]), showing competitive diagnostic accuracy and calibration. At the Youden's index, sensitivity was 0.72 (95% CI [0.68-0.76]), the highest of all. Analysis of predictions revealed that both atrial and ventricular strain CMR parameters were important for the identification of ICM patients. CONCLUSION: The current study demonstrated that using a ML model, multi chamber myocardial strain, and function on non-contrast CMR parameters enables the discrimination between ICM and NICM with competitive diagnostic accuracy. CLINICAL RELEVANCE STATEMENT: A machine learning model based on non-contrast cardiovascular magnetic resonance parameters may discriminate between ischemic and non-ischemic cardiomyopathy enabling wider access to cardiovascular magnetic resonance examinations with lower costs and faster imaging acquisition. KEY POINTS: • The exponential growth in cardiovascular magnetic resonance examinations may require faster and more cost-effective protocols. • Artificial intelligence models can be utilized to distinguish between ischemic and non-ischemic etiologies. • Machine learning using non-contrast CMR parameters can effectively distinguish between ischemic and non-ischemic cardiomyopathies.

15.
Med Image Anal ; 94: 103142, 2024 May.
Article in English | MEDLINE | ID: mdl-38492252

ABSTRACT

Cardiac cine magnetic resonance imaging (MRI) is a commonly used clinical tool for evaluating cardiac function and morphology. However, its diagnostic accuracy may be compromised by the low spatial resolution. Current methods for cine MRI super-resolution reconstruction still have limitations. They typically rely on 3D convolutional neural networks or recurrent neural networks, which may not effectively capture long-range or non-local features due to their limited receptive fields. Optical flow estimators are also commonly used to align neighboring frames, which may cause information loss and inaccurate motion estimation. Additionally, pre-warping strategies may involve interpolation, leading to potential loss of texture details and complicated anatomical structures. To overcome these challenges, we propose a novel Spatial-Temporal Attention-Guided Dual-Path Network (STADNet) for cardiac cine MRI super-resolution. We utilize transformers to model long-range dependencies in cardiac cine MR images and design a cross-frame attention module in the location-aware spatial path, which enhances the spatial details of the current frame by using complementary information from neighboring frames. We also introduce a recurrent flow-enhanced attention module in the motion-aware temporal path that exploits the correlation between cine MRI frames and extracts the motion information of the heart. Experimental results demonstrate that STADNet outperforms SOTA approaches and has significant potential for clinical practice.


Subject(s)
Heart , Magnetic Resonance Imaging, Cine , Humans , Magnetic Resonance Imaging, Cine/methods , Heart/diagnostic imaging , Motion , Neural Networks, Computer , Magnetic Resonance Imaging , Image Processing, Computer-Assisted/methods
16.
Phys Med Biol ; 69(6)2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38408387

ABSTRACT

Objective. Real-time MRgRT uses 2D-cine imaging for target tracking and motion evaluation. Rotation of gantry inducedB0off-resonance, resulting in image artifacts and imaging isocenter-shift precluding MR-guided arc therapy. Standard MRI phantoms designed for higher resolution images face challenges when low-resolution cine imaging is needed to achieve high frame rates. This work aimed to examine the spatial accuracy including geometric distortion and isocenter shift in real-time during gantry rotation on a 0.35 T MR-Linac using the concentric Cine imaging quality assurance (QA) phantom and its associated image analysis software.Approach. The Cine imaging QA phantom consists of two concentric shells of low-T1mineral oil and a central alignment structure. The phantom was scanned on three different MRI systems; 0.55 T Siemens Free.Max, 1.5 T Philips Ingenia, and 0.35 T ViewRay MRIdian MR-Linac using 2D balanced steady-state free precession (bSSFP) imaging sequence. In addition, bSSFP cine MRI with the banding artifact correction was tested on 0.35 T ViewRay MR-Linac. Images from the MR-Linac were acquired with the Linac gantry stationary and rotating from gantry 300°â†’ 0° and vice versa. Three orthogonal image planes were scanned excluding the 1.5 T Philips Ingenia, where only the axial plane was scanned. The image analysis software calculated the distortion values as well as the isocenter position for each cine frame.Main results. The geometric distortion of cine imaging on MRIs and MR-Linac at gantry stationary are within 1 mm while the substantial geometric distortion of 2 and 2.2 mm were observed on 0.35 T MR-Linac while rotating the gantry clockwise (300°â†’ 0°) and counterclockwise 0°â†’ 300° respectively. The average imaging isocenter shift was 0.1 mm for both MRIs and the static gantry and imaging isocenter shift of ≤1.5 mm was observed during the gantry rotation. The imaging isocenter shift decreased by 1 ± 0.2 mm clockwise and counterclockwise withB0compensation.Significance. The concentric Cine imaging QA phantom and its associated software effectively demonstrate the image distortion on real-time cine imaging on regular MRIs and 0.35 T MR-Linac. The results of significant geometric distortion with a rotating gantry in the MR-Linac system require further investigation to alleviate the extent of the image distortion.


Subject(s)
Image Processing, Computer-Assisted , Particle Accelerators , Image Processing, Computer-Assisted/methods , Software , Phantoms, Imaging , Magnetic Resonance Imaging/methods
17.
Front Cardiovasc Med ; 11: 1286271, 2024.
Article in English | MEDLINE | ID: mdl-38347952

ABSTRACT

Background: Due to its potential to significantly reduce scanning time while delivering accurate results for cardiac volume function, compressed sensing (CS) has gained traction in cardiovascular magnetic resonance (CMR) cine. However, further investigation is necessary to explore its feasibility and impact on myocardial strain results. Materials and methods: A total of 102 participants [75 men, 46.5 ± 17.1 (SD) years] were included in this study. Each patient underwent four consecutive cine sequences with the same slice localization, including the reference multi-breath-hold balanced steady-state free precession (bSSFPref) cine, the CS cine with the same flip angle as bSSFPref before (CS45) and after (eCS45) contrast enhancement, and the CS cine (eCS70) with a 70-degree flip angle after contrast enhancement. Biventricular strain parameters were derived from cine images. Two-tailed paired t-tests were used for data analysis. Results: Global radial strain (GRS), global circumferential strain (GCS), and global longitudinal strain (GLS) were observed to be significantly lower in comparison to those obtained from bSSFPref sequences for both the right and left ventricles (all p < 0.001). No significant difference was observed on biventricular GRS-LAX (long-axis) and GLS values derived from enhanced and unenhanced CS cine sequences with the same flip angle, but remarkable reductions were noted in GRS-SAX (short-axis) and GCS values (p < 0.001). After contrast injection, a larger flip angle caused a significant elevation in left ventricular strain results (p < 0.001) but did not affect the right ventricle. The increase in flip angle appeared to compensate for contrast agent affection on left ventricular GRS-SAX, GCS values, and right ventricular GRS-LAX, GLS values. Conclusion: Despite incorporating gadolinium contrast agents and applying larger flip angles, single breath-hold CS cine sequences consistently yielded diminished strain values for both ventricles when compared with conventional cine sequences. Prior to employing this single breath-hold CS cine sequence to refine the clinical CMR examination procedure, it is crucial to consider its impact on myocardial strain results.

18.
Sensors (Basel) ; 24(4)2024 Feb 18.
Article in English | MEDLINE | ID: mdl-38400470

ABSTRACT

Cardiac CINE, a form of dynamic cardiac MRI, is indispensable in the diagnosis and treatment of heart conditions, offering detailed visualization essential for the early detection of cardiac diseases. As the demand for higher-resolution images increases, so does the volume of data requiring processing, presenting significant computational challenges that can impede the efficiency of diagnostic imaging. Our research presents an approach that takes advantage of the computational power of multiple Graphics Processing Units (GPUs) to address these challenges. GPUs are devices capable of performing large volumes of computations in a short period, and have significantly improved the cardiac MRI reconstruction process, allowing images to be produced faster. The innovation of our work resides in utilizing a multi-device system capable of processing the substantial data volumes demanded by high-resolution, five-dimensional cardiac MRI. This system surpasses the memory capacity limitations of single GPUs by partitioning large datasets into smaller, manageable segments for parallel processing, thereby preserving image integrity and accelerating reconstruction times. Utilizing OpenCL technology, our system offers adaptability and cross-platform functionality, ensuring wider applicability. The proposed multi-device approach offers an advancement in medical imaging, accelerating the reconstruction process and facilitating faster and more effective cardiac health assessment.


Subject(s)
Algorithms , Magnetic Resonance Imaging , Heart/diagnostic imaging , Image Enhancement/methods , Imaging, Three-Dimensional/methods
19.
Radiol Cardiothorac Imaging ; 6(1): e230107, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38358330

ABSTRACT

Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.


Subject(s)
Magnetic Resonance Imaging, Cine , Magnetic Resonance Imaging , Adult , Humans , Male , Child , Middle Aged , Retrospective Studies , Tachypnea , Hyperventilation , Arrhythmias, Cardiac
20.
Head Face Med ; 20(1): 10, 2024 Feb 17.
Article in English | MEDLINE | ID: mdl-38365709

ABSTRACT

BACKGROUND: Real-time magnetic resonance imaging (rtMRI) is essential for diagnosing and comprehending temporomandibular joint (TMJ) movements. Current methods for tracking and analysis require manual landmark placement on each acquisition frame. Therefore, our study aimed to assess the inter- and intra-rater reliability of placing cephalometric landmarks in frames from a dynamic real-time TMJ MRI. MATERIAL AND METHODS: Four real-time MRIs of the right TMJ were taken during mandibular movement at ten frames per second. Seven dentists identified ten landmarks on two frames (intercuspal position-ICP-and maximum mouth opening-MMO) twice at a two-week interval, yielding 112 tracings. Six typical cephalometric measurements (angles and distances) were derived from these landmarks. The reliabilities of landmarks and measurements were evaluated using distance-based (dbICC), linear mixed effect model intraclass correlation (lmeICC), and standard ICC. RESULTS: The average inter-rater reliability for the landmarks stood at 0.92 (dbICC) and 0.93 (lmeICC). The intra-rater reliability scores were 0.97 and 0.98. Over 80% of the landmarks showed an ICC greater than 0.98 (inter-rater) and over 0.99 (intra-rater). The lowest landmark ICC was observed for the orbitale and the oblique ridge of the mandibular ramus. However, the cephalometric angle and distance measurements derived from these landmarks showed only moderate to good reliability, whereas the reliability in the frames with ICP was better than those with MMO. Measurements performed in the ICP frame were more reliable than measurements in the MMO frame. CONCLUSION: While dentists reliably localize isolated landmarks in real-time MRIs, the cephalometric measurements derived from them remain inconsistent. The better results in ICP than MMO are probably due to a more familiar jaw position. The higher error rate of the TMJ measurements in MMO could be associated with a lack of training in real-time MRI analysis in dentistry.


Subject(s)
Magnetic Resonance Imaging , Temporomandibular Joint , Humans , Reproducibility of Results , Temporomandibular Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Mandible , Cephalometry/methods , Observer Variation
SELECTION OF CITATIONS
SEARCH DETAIL
...